The effect of digital impressions on the marginal seal of full ceramic crowns: A systemic Paper

Authors

  • Amaal Khalleefah Altabeeb Faculty of Dentistry, University of Zawia. Author
  • Eyiman Abdulhakim Alshaybani Faculty of Dentistry, University of Zawia Author
  • Marwa Mawulud Elhtab Faculty of Dentistry, University of Zawia Author

DOI:

https://doi.org/10.54361/LJMR.19.1.07

Keywords:

impression, intra oral scanner, 3Dimaging, all ceramic restoration, marginal seal

Abstract

Purpose: A group of three-dimensional imaging techniques have been introduced and these techniques have revolutionized dentistry in general and dental prosthodontics in particular. This has led to an increase in the accuracy of traditional restorations, in addition to providing a virtual framework that includes all treatment strategies, from designing and manufacturing restorations digitally. On the other hand, the challenges related to obtaining oral impressions using traditional methods were highlighted through the use of intraoral scanners (IOSs), as this technology is considered more comfortable and convenient for patients and doctors(1).

Aim: This scientific paper aims to conduct a review of digital impression systems, their advantages, and disadvantages, as well as to evaluate the importance of the marginal seal of full ceramic crowns and to study the impact of digital impressions on them.

Methodology: original scientintific papers on effect of digital impressions on the marginal seal of full ceramic crowns published in the MEDLINE.

Results: A generation change occurs when the manufacturer upgrades an existing scanner (previous generation) in terms of both hardware and software, creating a new version (new generation model). The study concluded that new generations of intraoral scanner hardware and software can significantly increase the accuracy of the devices when it comes to scanning an entire dental arch, while all versions produce a clinically acceptable digital impression of a single abutment. 

Conclusion: There is no unison on what nominate a clinically acceptable maximum margin gap width. Furthermore, there is high widely between the systems and methodologies within the different studies which making it difficult to achieve direct comparison between the results of the academicals works. Based on the results of this systematic review all studies appear to indicate a predictable margin gap within or near clinically acceptable thresholds.

References

Kim RJY, Park JM, Shim JS. Accuracy of 9 intraoral scanners for complete-arch image acquisition: A qualitative and quantitative evaluation. J Prosthet Dent. 2018;120(6):895–903.

Ting-shu S, Jian S. Intraoral digital impression technique: a review. J Prosthodont. 2015;24(4):313–21.

Martin CB, Chalmers E V, McIntyre GT, Cochrane H, Mossey PA. Orthodontic scanners: what’s available? J Orthod. 2015;42(2):136–43.

Imburgia M, Logozzo S, Hauschild U, Veronesi G, Mangano C, Mangano FG. Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study. BMC Oral Health. 2017;17:1–13.

Aragón MLC, Pontes LF, Bichara LM, Flores-Mir C, Normando D. Validity and reliability of intraoral scanners compared to conventional gypsum models measurements: a systematic review. Eur J Orthod. 2016;38(4):429–34.

Doidge N. The brain that changes itself: Stories of personal triumph from the frontiers of brain science. Penguin; 2007.

Sehrawat S, Kumar A, Grover S, Dogra N, Nindra J, Rathee S, et al. Study of 3D scanning technologies and scanners in orthodontics. Mater Today Proc. 2022;56:186–93.

Hack GD, Bloom IT, Patzelt SBM. Digital impressions. Clin Appl Digit Dent Technol. 2015;27–40.

Mej’ia JBC, Wakabayashi K, Nakamura T, Yatani H. Influence of abutment tooth geometry on the accuracy of conventional and digital methods of obtaining dental impressions. J Prosthet Dent. 2017;118(3):392–9.

Suese K. Progress in digital dentistry: The practical use of intraoral scanners. Dent Mater J. 2020;39(1):52–6.

Baheti MJ, Soni UN, Gharat N V, Mahagaonkar P, Khokhani R, Dash S, et al. Intra-oral scanners: a new eye in dentistry. Austin J Orthop & Rheumatol. 2015;2(3):1023.

Abduo J, Lyons K, Swain M. Fit of zirconia fixed partial denture: a systematic review. J Oral Rehabil. 2010;37(11):866–76.

Xu D, Xiang N, Wei B. The marginal fit of selective laser melting--fabricated metal crowns: An in vitro study. J Prosthet Dent. 2014;112(6):1437–40.

Jacobs MS, Windeler AS. An investigation of dental luting cement solubility as a function of the marginal gap. J Prosthet Dent. 1991;65(3):436–42.

Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CHF, et al. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont. 2007;20(4):383.

Bergenholtz G, Cox CF, Loesche WJ, Syed SA. Bacterial leakage around dental restorations: its effect on the dental pulp. J Oral Pathol & Med. 1982;11(6):439–50.

Felton DA, Kanoy BE, Bayne SC al, Wirthman GP. Effect of in vivo crown margin discrepancies on periodontal health. J Prosthet Dent. 1991;65(3):357–64.

Layton D. A critical appraisal of the survival and complication rates of tooth-supported all-ceramic and metal-ceramic fixed dental prostheses: the application of evidence-based dentistry. Int J Prosthodont. 2011;24(5).

Rekow ED, Zhang G, Thompson V, Kim JW, Coehlo P, Zhang Y. Effects of geometry on fracture initiation and propagation in all-ceramic crowns. J Biomed Mater Res Part B Appl Biomater An Off J Soc Biomater Japanese Soc Biomater Aust Soc Biomater Korean Soc Biomater. 2009;88(2):436–46.

Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. J Prosthet Dent. 1989;62(4):405–8.

Sorensen JA. A standardized method for determination of crown margin fidelity. J Prosthet Dent. 1990;64(1):18–24.

Contrepois M, Soenen A, Bartala M, Laviole O. Marginal adaptation of ceramic crowns: a systematic review. J Prosthet Dent. 2013;110(6):447–54.

Kelly JR, Davis SH, Campbell SD. Nondestructive, three-dimensional internal fit mapping of fixed prostheses. J Prosthet Dent. 1989;61(3):368–73.

Laurent M, Scheer P, Dejou J, Laborde G. Clinical evaluation of the marginal fit of cast crowns--validation of the silicone replica method. J Oral Rehabil. 2008;35(2):116–22.

Boening KW, Wolf BH, Schmidt AE, Kästner K, Walter MH. Clinical fit of Procera AllCeram crowns. J Prosthet Dent. 2000;84(4):419–24.

Coli P, Karlsson S. Fit of a new pressure-sintered zirconium dioxide coping. Int J Prosthodont. 2004;17(1).

Assif D, Antopolski B, Helft M, Kaffe I. Comparison of methods of clinical evaluation of the marginal fit of complete cast gold crowns. J Prosthet Dent. 1985;54(1):20–4.

Dedmon HW. Disparity in expert opinions on size of acceptable margin openings. Oper Dent. 1982;7(3):97–101.

Mitchell CA, Pintado MR, Douglas WH. Nondestructive, in vitro quantification of crown margins. J Prosthet Dent. 2001;85(6):575–84.

Borba M, Miranda Jr WG, Cesar PF, Griggs JA, Bona A Della. Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology. Braz Oral Res. 2013;27(05):396–402.

Zinelis S. Micro-CT evaluation of the marginal fit of different In-Ceram alumina copings. Dep Prosthodont Sch Dent Natl Kapodistrian Univ. 2009;

Tuntiprawon M, Wilson PR. The effect of cement thickness on the fracture strength of all-ceramic crowns. Aust Dent J. 1995;40(1):17–21.

Jw M. The estimation of cement film thickness by an in vivo technique. Br dent j. 1971;131:107–11.

Mörmann WH, Bindl A, Lüthy H, Rathke A. Effects of preparation and luting system on all-ceramic computer-generated crowns. Int J Prosthodont. 1998;11(4).

Rossetti PHO, Valle AL do, Carvalho RM de, Goes MF De, Pegoraro LF. Correlation between margin fit and microleakage in complete crowns cemented with three luting agents. J Appl Oral Sci. 2008;16:64–9.

Scherrer SS, De Rijk WG, Belser UC, Meyer JM. Effect of cement film thickness on the fracture resistance of a machinable glass-ceramic. Dent Mater. 1994;10(3):172–7.

Boeckler AF, Stadler A, Setz JM. The significance of marginal gap and overextension measurement in the evaluation of the fit of complete crowns. J Contemp Dent Pr. 2005;6(4):26–37.

Kohorst P, Brinkmann H, Li J, Borchers L, Stiesch M. Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems. Eur J Oral Sci. 2009;117(3):319–25.

Lopez-Suarez C, Gonzalo E, Pelaez J, Serrano B, Suarez MJ. Marginal Vertical Discrepancies of Monolithic and Veneered Zirconia and Metal-Ceramic Three-Unit Posterior Fixed Dental Prostheses. Int J Prosthodont. 2016;29(3):256–8.

Grenade C, Mainjot A, Vanheusden A. Fit of single tooth zirconia copings: comparison between various manufacturing processes. J Prosthet Dent. 2011;105(4):249–55.

Ayad MF. Effects of tooth preparation burs and luting cement types on the marginal fit of extracoronal restorations. J Prosthodont Implant Esthet Reconstr Dent. 2009;18(2):145–51.

Han HS, Yang HS, Lim HP, Park YJ. Marginal accuracy and internal fit of machine-milled and cast titanium crowns. J Prosthet Dent. 2011;106(3):191–7.

Song HY, Cho LR. Marginal accuracy and fracture strength of Targis/Vectris Crowns prepared with different preparation designs. J Korean Acad Prosthodont. 2000;38(6):791–9.

Yüksel E, Zaimouglu A. Influence of marginal fit and cement types on microleakage of all-ceramic crown systems. Braz Oral Res. 2011;25:261–6.

Kaleli N, Saraç D. Comparison of porcelain bond strength of different metal frameworks prepared by using conventional and recently introduced fabrication methods. J Prosthet Dent. 2017;118(1):76–82.

Beuer F, Aggstaller H, Edelhoff D, Gernet W. Effect of preparation design on the fracture resistance of zirconia crown copings. Dent Mater J. 2008;27(3):362–7.

Goodacre CJ, Campagni W V, Aquilino SA. Tooth preparations for complete crowns: an art form based on scientific principles. J Prosthet Dent. 2001;85(4):363–76.

Quaas S, Rudolph H, Luthardt RG. Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations. J Dent. 2007;35(12):903–8.

Luthardt RG, Loos R, Quaas S. Accuracy of intraoral data acquisition in comparison to the conventional impression. Int J Comput Dent. 2005;8(4):283–94.

Güth JF, Keul C, Stimmelmayr M, Beuer F, Edelhoff D. Accuracy of digital models obtained by direct and indirect data capturing. Clin Oral Investig. 2013;17:1201–8.

Uhm SH, Kim JH, Jiang HB, Woo CW, Chang M, Kim KN, et al. Evaluation of the accuracy and precision of four intraoral scanners with 70% reduced inlay and four-unit bridge models of international standard. Dent Mater J. 2017;36(1):27–34.

Syrek A, Reich G, Ranftl D, Klein C, Cerny B, Brodesser J. Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent. 2010;38(7):553–9.

Zarauz C, Valverde A, Martinez-Rus F, Hassan B, Pradies G. Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions. Clin Oral Investig. 2016;20:799–806.

Brawek PK, Wolfart S, Endres L, Kirsten A, Reich S. The clinical accuracy of single crowns exclusively fabricated by digital workflow—the comparison of two systems. Clin Oral Investig. 2013;17:2119–25.

Pak HS, Han JS, Lee JB, Kim SH, Yang JH. Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns. J Adv Prosthodont. 2010;2(2):33–8.

Endera A, Mehlb A. Influence of Scanning Strategies on the Accuracy of Digital Intraoral Scanning Systems Einfluss von Scanstrategien auf die Genauigkeit von digitalen intraoralen Scansystemen. Int J Comput Dent. 2013;16:11–21.

Seelbach P, Brueckel C, Wöstmann B. Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig. 2013;17:1759–64.

Abdel-Azim T, Rogers K, Elathamna E, Zandinejad A, Metz M, Morton D. Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology by using conventional impressions and two intraoral digital scanners. J Prosthet Dent. 2015;114(4):554–9.

e Silva JS, Erdelt K, Edelhoff D, Araújo É, Stimmelmayr M, Vieira LCC, et al. Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig. 2014;18:515–23.

Shembesh M, Ali A, Finkelman M, Weber HP, Zandparsa R. An in vitro comparison of the marginal adaptation accuracy of CAD/CAM restorations using different impression systems. J Prosthodont. 2017;26(7):581–6.

Park JM. Comparative analysis on reproducibility among 5 intraoral scanners: sectional analysis according to restoration type and preparation outline form. J Adv Prosthodont. 2016;8(5):354–62.

Tidehag P, Ottosson K, Sjögren G. Accuracy of ceramic restorations made using an in-office optical scanning technique: an in vitro study. Oper Dent. 2014;39(3):308–16.

Pedroche LO, Bernardes SR, Leão MP, Kintopp CC de A, Correr GM, Ornaghi BP, et al. Marginal and internal fit of zirconia copings obtained using different digital scanning methods. Braz Oral Res. 2016;30(1):e113.

Dauti R, Cvikl B, Franz A, Schwarze UY, Lilaj B, Rybaczek T, et al. Comparison of marginal fit of cemented zirconia copings manufactured after digital impression with lavaTM COS and conventional impression technique. BMC Oral Health. 2016;16:1–8.

Su S, Dudley J. The marginal gaps of lithium disilicate crowns constructed by different scanner and milling unit combinations. Aust Dent J. 2022;67(2):125–31.

Schmidt A, Klussmann L, Wöstmann B, Schlenz MA. Accuracy of digital and conventional full-arch impressions in patients: an update. J Clin Med. 2020;9(3):688.

Vág J, Renne W, Revell G, Ludlow M, Mennito A, Teich ST, et al. The effect of software updates on the trueness and precision of intraoral scanners. Quintessence Int. 2021;52(7):636–44.

Schmalzl J, Róth I, Borbély J, Hermann P, Vecsei B. The impact of software updates on accuracy of intraoral scanners. BMC Oral Health. 2023;23(1):219.

Downloads

Published

01-01-2025

Issue

Section

Articles

How to Cite

1.
Altabeeb A, Alshaybani E, Elhtab M. The effect of digital impressions on the marginal seal of full ceramic crowns: A systemic Paper . LJMR [Internet]. 2025 Jan. 1 [cited 2025 Feb. 5];19(1):35-49. Available from: http://ljmr.ly/index.php/ljmr/article/view/307